Product Details:

  • Function Controls solenoid valve for timed opening/closing
  • Thread size 1/4 inch
  • Max Pressure 16 bar
  • Working Temperature -10C to +50C
  • Mechanical Life >1 million cycles
  • Product Type Purge Timer
  • Max. Current 16A
  • Click to View more
X

Purge Timers Price And Quantity

  • 100-200 Piece

Purge Timers Product Specifications

  • -10C to +50C
  • 200g
  • IP65
  • >1 million cycles
  • Black and Yellow
  • 0-16 bar
  • 230V AC
  • 16 bar
  • Automatic drain valve cycling, compressed air systems, condensate removal
  • Relay output
  • 1/4 inch
  • 98 x 64 x 36 mm
  • 16A
  • Purge Timer
  • 3500W
  • Controls solenoid valve for timed opening/closing

Purge Timers Trade Information

  • 1000 Piece Per Week
  • 1 Week

Product Description

With experience of many successful years, we are affianced in offering excellent quality Purge Timers. Widely demanded to install in modules and controls, these timers are used for providing pre purge timing. These timers are manufactured under the guidance of our experts using optimal grade materials. In addition, these Purge Timers are offered to our clients in numerous specifications at affordable rates.

 

 

Features:

 

  • Rugged design

  • High operational fluency

  • Unmatched performance

 

Purge Timers ST7800A



Reliable Control for Drain Valves

This digital timer automates solenoid valve operation for effective condensate management in compressed air systems. With adjustable interval and discharge settings, facilities can tailor their cycling for optimal performance. The units relay output and LED power indication enhance reliability and user awareness during operation.


Durable and Versatile Construction

Built from flame retardant ABS and protected to IP65 standards, the Purge Timer withstands harsh industrial environments. Its compact size, robust mechanism, and flexible mounting options make installation practical for diverse sites. Operators benefit from a mechanical life exceeding one million cycles, suitable for heavy-duty use.

FAQs of Purge Timers:


Q: How do I set the interval and discharge times on the Purge Timer?

A: The Purge Timer features digital controls that allow users to set the interval time between 0.5 and 45 minutes and the discharge time between 0.5 and 10 seconds. Adjust these settings using the timers interface to match your applications specific condensate removal needs.

Q: What advantages does the flame retardant ABS body provide?

A: Flame retardant ABS material enhances safety by reducing the risk of fire and ensures durability against industrial wear. This makes the timer suitable for demanding environments such as compressed air systems, maintaining performance and safety over long-term usage.

Q: When is it necessary to use a purge timer in a compressed air system?

A: A purge timer is essential when consistent and automated drain valve cycling is needed for effective condensate removal. Use it during regular operation to prevent water accumulation, system corrosion, and maintain air quality within compressed air setups.

Q: Where can the Purge Timer be installed within an industrial system?

A: The device can be mounted on DIN rails or panels, offering flexibility for installation in control panels or directly on machinery. Always ensure it connects to compatible solenoid drain valves and maintains protection against moisture and dust, as per its IP65 rating.

Q: What is the process for wiring and connecting the Purge Timer to a solenoid valve?

A: Install the timer following the supplied schematic, ensuring relay output connects to the solenoid valve and that supply voltage matches its 230V AC specification. Secure wiring, observe polarity, and verify LED power indication for operational readiness.

Q: How does the timer improve condensate removal in compressed air systems?

A: By automatically controlling the timed opening and closing of solenoid valves, the purge timer ensures regular and efficient discharge of condensate, preventing build-up, system damage, and downtime. This process enhances system longevity and reduces maintenance demands.

Q: What are the benefits of using a timer with an LED power indication and IP65 protection?

A: LED indication offers immediate visual confirmation of device power status, contributing to operational confidence. IP65 protection ensures resistance to dust and water ingress, increasing reliability and reducing risk during both indoor and outdoor industrial applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Honeywell Combustion Control Products ' category




Kolkata Office

S.L. Sarani,
Gautam Para, Baguiati
Kolkata-700059 ( India )
Bangalore Office

No. 11, Old No.298,
9th 'A' Main, 1st Corss,
Chairman Layout, Dodda Bansawadi,
Opp. Shrinidhi Upachar Hotel ,
Bangalore-560043 ( India )
Ludhiana Office

House No. 3721, Gali No. 7,
Baba Deep Singh Nagar,
Opp.Transport Nagar,
Ludhiana,Punjab,( India )
Mumbai Office

Flat No. B/001, Ground Floor,
Krishna Sagar Apartment, Link Road,
Nallasopara, Vasant Nagar,
Vasai (E) Thane-401209
Maharashtra , ( India )

Back to top