Honeywell Satronic Burner Controls Specification

  • Function
  • Automatic Burner Control and Safety Unit
  • Mechanical Life
  • More than 1 million operations
  • Working Temperature
  • -20C to +60C
  • Product Type
  • Burner Control Unit
  • Max. Current
  • 5 A
  • Max. Power
  • 1200 W
  • Max. Voltage
  • 220-240 V AC
  • Protection Class
  • IP40
  • Application
  • Oil and Gas Burners, Industrial Burners, Heating Systems
  • Output Signal
  • Relay Output
  • Size
  • 96 x 96 x 52 mm (approx.)
  • Color
  • Black / Yellow
  • Weight
  • Approx. 250 g
  • Flame Detection
  • Photo Resistive Cell / UV Cell
  • Model Compatibility
  • Applicable for various Honeywell Satronic models (e.g., TFI 812.2, DKO 972)
  • Storage Temperature
  • -25C to +85C
  • Ambient Humidity
  • 10% to 90% RH, non-condensing
  • Reset Type
  • Manual and Automatic
  • Mounting Type
  • DIN Rail / Panel Mount
  • Supply Frequency
  • 50/60 Hz
  • Response Time
  • < 1 s
  • Enclosure Material
  • High Impact Plastic
  • Ignition Type
  • Direct Electrodes
 

Honeywell Satronic Burner Controls Trade Information

  • Minimum Order Quantity
  • 100-200 Pieces
  • Supply Ability
  • 1000 Pieces Per Week
  • Delivery Time
  • 1 Week
 

About Honeywell Satronic Burner Controls

With the assistance of our adroit technical experts, we are engrossed in exporting and supplying an extensive range of Honeywell Satronic Burner Controls. Built with flame safeguard option, the offered products are used in controlling and monitoring oil power burner and greatly improves efficiency and functioning. At vendors' end, these products are manufactured with the usage of superior quality components and ultra-modern technology in sync with set market norms. Also, clients can avail these Honeywell Satronic Burner Controls from us in various specific options as per application requirement.

Features:

  • Fully compatible with existing control systems
  • Electrical remote reset
  • Bridging contact for oil preheater
  • Equipped with monitoring of time for oil preheater
  • Accurate and reproducible control
  • Controlled intermittent operation after 24 hours of continuous operation
  • Limitation of the number of repetitions
  • Multicolor indication of fault status and operational status messages


Reliable Burner Control for Industrial Needs

Honeywell Satronic Burner Controls offer fast and accurate burner management by featuring rapid response times under 1 second and flexible installation options. Compatible with diverse Honeywell Satronic models like TFI 812.2 and DKO 972, these units suit applications in oil burners, gas burners, and heating systems. Designed to withstand demanding operating and storage temperatures, they provide consistent safety and reliable output throughout their life cycle.


Advanced Flame Detection and Ignition

Equipped with photo-resistive or UV cells for flame detection and direct electrode ignition, these controls enhance burner safety and efficiency. Relays facilitate swift output signaling, while manual and automatic reset features allow easy recovery and minimal downtime. High-impact plastic enclosures offer protection, and precise engineering ensures operation under varied humidity and temperature ranges.

FAQs of Honeywell Satronic Burner Controls:


Q: How do the Honeywell Satronic Burner Controls improve burner safety?

A: These burner controls use advanced flame detection techniquesphoto-resistive or UV cellsand direct electrode ignition to monitor and control burner operation in real-time, ensuring prompt shutdown in case of irregularities and thereby improving overall safety.

Q: What types of mounting options are available for these controls?

A: Honeywell Satronic Burner Controls can be installed using either DIN rail mounting or traditional panel mounting methods, offering flexibility for various industrial setups and space requirements.

Q: When is it necessary to use manual versus automatic reset on the burner control unit?

A: Manual reset is typically used after a safety or fault shutdown to ensure operator intervention before restarting, while automatic reset can be set for uninterrupted operation when minor faults or temporary interruptions occur, promoting safety and operational continuity.

Q: Where can the Honeywell Satronic Burner Controls be applied?

A: These controls are designed for use in oil and gas burners, industrial burner systems, and heating equipment. They are widely suited for manufacturing, processing, and commercial installations throughout India.

Q: What process does the burner controller follow after flame detection?

A: Once a flame is detected via the photo-resistive cell or UV cell, the controller signals the relay output to continue burner operation. If no flame is detected, the system triggers a shutdown and, depending on the reset type, may await manual restart or initiate automatic recovery.

Q: How does the response time benefit burner operation?

A: A response time of less than one second ensures the burner reacts instantly to flame presence and faults, minimizing risk and enhancing both safety and efficiency during each operational cycle.

Q: What are the benefits of the high-impact plastic enclosure and IP40 protection?

A: The high-impact plastic enclosure provides durable protection against environmental factors, while IP40 rating safeguards against solid object intrusion, making the control unit reliable for long-term industrial use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Honeywell Combustion Control Products Category

Pressure Controllers

Pressure Controllers

Minimum Order Quantity : 100200 Pieces

Function : Automatic pressure switching and protection

Protection Class : IP65

Max. Voltage : 220 V AC

Color : Blue/Black

Oil Preheaters

Oil Preheaters

Minimum Order Quantity : 100200 Pieces

Function : Heating and maintaining oil temperature

Protection Class : IP55

Max. Voltage : 230 V AC

Color : Grey

Purge Timers

Purge Timers

Minimum Order Quantity : 100200 Pieces

Function : Controls solenoid valve for timed opening/closing

Protection Class : IP65

Max. Voltage : 230V AC

Color : Black and Yellow

Photo Cell Flame Detectors

Photo Cell Flame Detectors

Minimum Order Quantity : 100200 Pieces

Function : Detects presence of visible flame in combustion systems

Protection Class : IP54

Max. Voltage : 220 V AC

Color : Black/Yellow




Kolkata Office

S.L. Sarani,
Gautam Para, Baguiati
Kolkata-700059 ( India )
Bangalore Office

No. 11, Old No.298,
9th 'A' Main, 1st Corss,
Chairman Layout, Dodda Bansawadi,
Opp. Shrinidhi Upachar Hotel ,
Bangalore-560043 ( India )
Ludhiana Office

House No. 3721, Gali No. 7,
Baba Deep Singh Nagar,
Opp.Transport Nagar,
Ludhiana,Punjab,( India )
Mumbai Office

Flat No. B/001, Ground Floor,
Krishna Sagar Apartment, Link Road,
Nallasopara, Vasant Nagar,
Vasai (E) Thane-401209
Maharashtra , ( India )

Back to top