Siemens Oil Burner Controller LMO24
Siemens Oil Burner Controller LMO24

Siemens Oil Burner Controller LMO24

MOQ : 100-200 Pieces

Siemens Oil Burner Controller LMO24 Specification

  • Condition
  • New
  • Type
  • Oil Burner Controller
  • Usage
  • Industrial
  • Structure
  • Compact, Modular
  • Pressure
  • Standard Operating Pressure
  • Style
  • Electronic
  • Material
  • High Grade Plastic and Electronic Components
  • Application
  • For use in single or multi-stage oil burners
  • Control Cycle
  • Fully Automatic Burner Sequencing
  • Voltage
  • 220-240V AC
  • Mounting
  • Base Mounted
  • Frequency
  • 50/60 Hz
  • Reset Feature
  • Manual and Auto Reset Option
  • Dimensions
  • 96 mm x 96 mm x 38 mm (approx.)
  • Protection Class
  • IP40
  • Flame Sensing
  • Photoresistor or Ionization Electrode Inputs
  • Weight
  • Approx. 160g
  • Switching Capacity
  • 3A (resistive)
  • Model Number
  • LMO24
  • Ambient Temperature
  • -20°C to +60°C
 

Siemens Oil Burner Controller LMO24 Trade Information

  • Minimum Order Quantity
  • 100-200 Pieces
  • FOB Port
  • Delhi
  • Payment Terms
  • Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 7 Days
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • All India
 

About Siemens Oil Burner Controller LMO24

Siemens Oil Burner Controller LMO24

Model No -  LMO24.114C2

Specifications :-

  •  230 V~
  •  50-60 Hz
  • TSAmax. - 10s.

Also Available Model no - LMO24.255C2

Technical Specification

Source

Electric

Usage/Application

Industrial

Brand

Siemens

Power

3VA

Frequency

50 - 60 Hz

Automation Grade

Automatic

Color

Black

Model Name/Number

LMO24



Efficient Burner Control

The Siemens LMO24 controller delivers streamlined, fully automatic sequencing for oil burners, enhancing operational efficiency and safety in industrial settings. This state-of-the-art unit adjusts seamlessly through both single and multi-stage systems, providing consistently reliable ignition, monitoring, and shutdown functions to safeguard equipment and processes.


Flexible Flame Sensing

Featuring compatibility with both photoresistor and ionization electrode inputs, the LMO24 offers adaptable flame detection to match a range of burner requirements. This dual-sensing capability ensures accurate flame monitoring for increased burner safety and reduces downtime due to false readings or system interruptions.


Durable, Compact Design

Engineered using high-grade plastic and quality electronic components, the compact 96x96x38 mm module incorporates IP40 protection, making it suitable even in challenging environments. Its robust construction supports ambient temperatures from -20C to +60C, ensuring dependable operation across various industrial conditions.

FAQs of Siemens Oil Burner Controller LMO24:


Q: How is the Siemens LMO24 Oil Burner Controller installed?

A: The LMO24 controller is base-mounted, making it straightforward to install within control panels or burner enclosures. Its compact design and modular structure facilitate integration in new and existing burner systems without demanding extensive space or special tools.

Q: What types of burners can the LMO24 controller be used with?

A: This controller is engineered for both single and multi-stage oil burners, making it versatile for a wide range of industrial applications. It is suitable for systems where precise, automated burner sequencing is essential.

Q: When should the manual or auto reset feature be used?

A: The manual and auto reset options provide flexibility in system management. Manual reset is ideal for maintenance or troubleshooting, ensuring user intervention after faults. Auto reset supports uninterrupted operation in applications where minimizing downtime is critical.

Q: Where can the LMO24 controller operate effectively?

A: With its IP40 protection rating and ability to withstand ambient temperatures from -20C to +60C, the LMO24 functions reliably in diverse industrial settings, including factories, processing plants, and boiler rooms across India and similar climates.

Q: What is the benefit of dual flame sensing inputs?

A: Dual flame sensing capability (photoresistor or ionization electrode) enhances operational safety by providing options to tailor flame detection to specific burner models or fuel types, reducing the risk of burner misoperation and improving system reliability.

Q: How does the fully automatic burner sequencing process work?

A: Once powered, the LMO24 manages ignition, flame monitoring, fuel valve operation, and safety shutdowns automatically, ensuring correct burner operation throughout each cycle without the need for manual supervision.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Siemens Oil Burner Controls Category

Siemens Oil Controller LAL2.25

Siemens Oil Controller LAL2.25

Minimum Order Quantity : 100200 Pieces

Type : Others, Oil Burner Controller

Condition : New

Style : Panel Mount

Pressure : Others, Standard Atmospheric

Siemens Oil Burner Sequence Controller LMO44

Siemens Oil Burner Sequence Controller LMO44

Minimum Order Quantity : 100200 Pieces

Type : Others, Oil Burner Sequence Controller

Condition : New

Style : Electronic Controller

Pressure : Others, Standard

Siemens Sequence Controller LAL1.25

Siemens Sequence Controller LAL1.25

Minimum Order Quantity : 100200 Pieces

Type : Others, Sequence Controller

Condition : New

Style : Screw Terminal

Pressure : Others, Normal

Siemens Oil Burner Controls

Siemens Oil Burner Controls

Minimum Order Quantity : 100200 Pieces

Type : Others, Oil Burner Control

Condition : New

Style : Panel Mounted

Pressure : Others, Normal




Kolkata Office

S.L. Sarani,
Gautam Para, Baguiati
Kolkata-700059 ( India )
Bangalore Office

No. 11, Old No.298,
9th 'A' Main, 1st Corss,
Chairman Layout, Dodda Bansawadi,
Opp. Shrinidhi Upachar Hotel ,
Bangalore-560043 ( India )
Ludhiana Office

House No. 3721, Gali No. 7,
Baba Deep Singh Nagar,
Opp.Transport Nagar,
Ludhiana,Punjab,( India )
Mumbai Office

Flat No. B/001, Ground Floor,
Krishna Sagar Apartment, Link Road,
Nallasopara, Vasant Nagar,
Vasai (E) Thane-401209
Maharashtra , ( India )

Back to top