Siemens Oil Burner Sequence Controller LMO44 Specification

  • Condition
  • New
  • Type
  • Oil Burner Sequence Controller
  • Usage
  • Industrial
  • Structure
  • Compact Solid-State Module
  • Pressure
  • Standard
  • Style
  • Electronic Controller
  • Material
  • High-grade Plastic Housing
  • Ambient Temperature
  • -20°C to +60°C
  • Protection Class
  • IP40
  • Frequency
  • 50/60 Hz
  • Voltage
  • 230V AC
  • Mounting
  • Socket and Plug-in Base
  • Flame Monitoring
  • Photo Resistor (QRB) or Ionization Electrode
  • Model
  • LMO44
  • Reset Type
  • Manual/Automatic
 

Siemens Oil Burner Sequence Controller LMO44 Trade Information

  • Minimum Order Quantity
  • 100-200 Pieces
  • FOB Port
  • Delhi
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 7 Days
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • All India
 

About Siemens Oil Burner Sequence Controller LMO44

Siemens Oil Burner Sequence Controller LMO44

Model No - LMO44.255C2

Specifications :-

  • 230 V~
  • 50-60 Hz
  • TSAmax.- 5s.

Technical Specification

IP Rating

IP68

Usage/Application

Industrial

Brand

Siemens

Voltage

230 V

Frequency

50 - 60 Hz

Automation Grade

Automatic

Color

Black

Packaging Type

Box

Model Name/Number

LMO 44.255




Safety and Reliability in Industrial Applications

The Siemens LMO44 Oil Burner Sequence Controller is crafted to deliver dependable control and safety for oil-fired burners in industrial settings. Featuring solid-state construction and advanced flame monitoring via either a photo resistor or ionization electrode, it ensures consistent performance under demanding conditions. The controllers IP40 protection class and wide ambient temperature tolerance further contribute to its reliability in harsh environments.


Flexible Installation and Easy Maintenance

Designed for convenience, the LMO44 utilizes a socket and plug-in base for quick and straightforward installation. Maintenance is simplified by the plug-in structure, enabling efficient replacement or servicing without complex wiring or prolonged system downtime. Its compact form allows it to fit seamlessly into control panels, maximizing space efficiency while safeguarding long-term operability.

FAQs of Siemens Oil Burner Sequence Controller LMO44:


Q: How does the Siemens LMO44 monitor the burner flame?

A: The LMO44 can monitor the flame using either a photo resistor (QRB) or an ionization electrode, ensuring accurate flame detection and enhancing burner safety during operation.

Q: What is the process for installing the LMO44 sequence controller?

A: The controller is designed for easy installation using a socket and plug-in base. This modular approach minimizes wiring complexity and allows for quick insertion or removal during setup and servicing.

Q: Where can the Siemens LMO44 be used effectively?

A: This sequence controller is ideal for industrial oil burner systems, particularly where robust control, reliable flame monitoring, and adaptable mounting options are required. Its wide ambient temperature range suits various industrial environments.

Q: What are the benefits of the manual and automatic reset functions?

A: The dual reset functions offer flexibility and safety: manual reset allows users to investigate before restarting after a fault, while automatic reset enables the controller to resume operations without manual intervention, enhancing system uptime.

Q: When should the LMO44 be considered over other controllers?

A: The LMO44 is a suitable choice when precise electronic control, reliable safety features, and flexible flame monitoring are required, especially under standard industrial pressure and environments demanding durable, compact design.

Q: What protection does the IP40 rating provide?

A: An IP40 protection class ensures the internal electronics are shielded from solid objects over 1mm in size, such as most tools and wires, contributing to longevity and safety in industrial settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Siemens Oil Burner Controls Category

Siemens Oil Burner Controller LMO24

Siemens Oil Burner Controller LMO24

Minimum Order Quantity : 100200 Pieces

Usage : Industrial

Condition : New

Pressure : Others, Standard Operating Pressure

Type : Others, Oil Burner Controller

Siemens Oil Controller LAL2.25

Siemens Oil Controller LAL2.25

Minimum Order Quantity : 100200 Pieces

Usage : Industrial

Condition : New

Pressure : Others, Standard Atmospheric

Type : Others, Oil Burner Controller

Siemens Sequence Controller LAL1.25

Siemens Sequence Controller LAL1.25

Minimum Order Quantity : 100200 Pieces

Usage : Industrial

Condition : New

Pressure : Others, Normal

Type : Others, Sequence Controller

Siemens Oil Burner Controls

Siemens Oil Burner Controls

Minimum Order Quantity : 100200 Pieces

Usage : Others, Industrial Oil Burner Automation

Condition : New

Pressure : Others, Normal

Type : Others, Oil Burner Control




Kolkata Office

S.L. Sarani,
Gautam Para, Baguiati
Kolkata-700059 ( India )
Bangalore Office

No. 11, Old No.298,
9th 'A' Main, 1st Corss,
Chairman Layout, Dodda Bansawadi,
Opp. Shrinidhi Upachar Hotel ,
Bangalore-560043 ( India )
Ludhiana Office

House No. 3721, Gali No. 7,
Baba Deep Singh Nagar,
Opp.Transport Nagar,
Ludhiana,Punjab,( India )
Mumbai Office

Flat No. B/001, Ground Floor,
Krishna Sagar Apartment, Link Road,
Nallasopara, Vasant Nagar,
Vasai (E) Thane-401209
Maharashtra , ( India )

Back to top